Multimode Microplate Reader with Advanced Detection Capabilities

  • Luminescence, fluorescence, UV-visible absorbance, BRET and FRET detection
  • 6- to 384-well microplate reader
  • Optimized with Promega cell viability and genetic reporter assays

Choose a size

Catalog number selected: GM3000

Your price: Log in

Add to Cart

This product is discontinued

Request a demo

This product is available under ourEarly Accessprogram - Learn More

This product is available under our Catalog (FT)program - Learn More

GloMax® Discover Microplate Reader

1 each

Your price: Log in

Easy-to-Use Plate Reader

GloMax® Discover is a ready-to-use multimode plate reader developed with Promega reagent chemistries to provide a simple means of detecting luminescence, fluorescence and absorbance. This advanced plate reader provides flexible use of filters and includes high-performance luminescence, fluorescence, UV-Visible absorbance, BRET and FRET, two-color filtered luminescence and kinetic measurement capabilities. GloMax® Discover can be used as a standalone plate reader or integrated into high-throughput automated workflows. Results are easy to interpret using integrated data analysis software.

GloMax® Discover Microplate Reader | Plate Reader (4)

Performance

GloMax® Discover multimode microplate reader delivers maximum flexibility with minimal user intervention and can be integrated into low- and medium-throughput automation workflows. The instrument provides superior luminescence sensitivity and dynamic range for both strong and weak bioluminescence experimental samples, as well as seamless integration with Promega bioluminescent cell and gene reporter assays.

GloMax® Discover Microplate Reader | Plate Reader (6)
  • Simple touch screen navigation with full PC capabilities
  • Choose from over 50 preloaded protocols and spend less time optimizing
  • Build custom protocols using the intuitive drag-and-drop interface
  • Export data to a network, cloud or any drive desired
GloMax® Discover Microplate Reader | Plate Reader (7)
  • Filter paddles and automatic filter switching allow easy two-color multiplexing assays or kinetic studies
  • Quick read-speeds for high efficiencies in your laboratory
  • Compatible for 3rd party automation control and data export to LIMS
GloMax® Discover Microplate Reader | Plate Reader (8)
  • Plate mask (aperture control) for switching between 96-well and 384-well plates
  • Low cross-talk between wells gives you better, more usable results
  • Broad dynamic range of the instrument extends the linear range of your assay
GloMax® Discover Microplate Reader | Plate Reader (9)
  • IQ/OQ Service available
  • Provides the required technical elements of a part 11 compliant system when used with the appropriate laboratory workflow:
    • User Authentication and Authorization
    • Data Integrity and Protection
    • Electronic Signatures
    • Audit Trails

Accurate Results from Every Well

There are three ways that microplate readers can affect how much useful information you get from each plate. Poor sensitivity may cause you to miss low-level samples that could be the “hit” you are looking for. Letting the signal from bright wells spill into adjacent wells allows crosstalk to occur and skews your experimental results. And a narrow detection range limits the accuracy and reproducibility that your work requires. With the GloMax® plate readers, you can rest easy and have confidence in your results.

GloMax® Discover Microplate Reader | Plate Reader (10)

Glomax® microplate readers offer superior sensitivity and auto-gain adjustment letting you measure weak and strong signals on the same plate.

GloMax® Discover Microplate Reader | Plate Reader (11)

The masking design of GloMax® microplate readers means you can be confident that the results from each well are not skewed by signal from neighboring wells.

GloMax® Discover Microplate Reader | Plate Reader (12)

With the broad detection range of GloMax® microplate readers, you can measure signals ranging from high intensity to near physiological levels.

Easier, Faster Data Analysis with GloMax® Plate Readers

GloMax® plate readers have high sensitivity and a wide dynamic range, so you candetect both high and low signals on the same plate and have confidence in the accuracyof the signal recorded from each well. These instruments provide a range of optionsfor your throughput needs and are equipped with integrated software that makes dataanalysis easy. GloMax® instruments come preloaded with protocols designed to workseamlessly with a wide variety of Promega luminescent and fluorescence-based assaysat the touch of a button, including the Lumit™ Dx SARS-CoV-2 Immunoassay, CellTiter-Glo® Luminescent Cell Viability Assay, and the Nano-Glo®Luciferase Assay System.

No need to reinvent the wheel—we’ve already used GloMax® instruments for everything from cell viability, toxicity and metabolism, kinase and cell signaling, reporter gene assays, nucleic acid quantitation for NGS sequencing, PROTACs and protein degradation, bioassays, BRET, ELISAs and even water quality testing. Search our collection of protocols and data generated using a variety of different luminescent and fluorescence-based assays on the GloMax® Instruments.

Explore GloMax® Application Notes

GloMax® Discover Microplate Reader | Plate Reader (13)

Pre-installed Assay Protocols
ADCC Reporter Bioassay ADP-Glo ApoLive-Glo Apo-ONE ApoTox-Glo
Autophagy HiBiT Reporter Assay BacTiter-Glo BCA Protein Assay** Bio-Glo Bradford Assay**
Bright-Glo cAMP-Glo Caspase-Glo CellTiter 96 AQ ONE** CellTiter-Blue
CellTiter-Fluor CellTiter-Glo CellTiter-Green Cholesterol/Cholesterol Ester-Glo Chroma-Glo*
Coumerin/Fluorescein Z-LYTE FRET* CytoTox-Fluor CytoTox-Glo CytoTox-ONE Dual Luciferase Assay
Dual-Glo ELISA (450nm)** GFP Protein Quantitation GloSensor cAMP Glucose Uptake-Glo
GTPase-Glo Glycerol-Glo Kinase-Glo Lactate-Glo LDH-Glo
Luciferase Assay System Lumit Immunoassay Mitochondrial ToxGlo MultiTox-Fluor MultiTox-Glo
NAD(P)H-Glo NADP/NADPH-Glo NanoBRET 618** Nano-DLR Nano-Glo®
Nano-Glo® Endurazine Nano-Glo® Live Cell Nano-Glo® Live Cell (NanoBiT) Nano-Glo® Vivazine ONE-Glo
ONE-Glo+Tox P450-Glo QuantiFluor dsDNA QuantiFluor ONE dsDNA QuantiFluor RNA
QuantiFluor ssDNA RealTime-Glo RealTime-Glo Annexin V Renilla Luciferase Assay System Renilla-Glo
Renilla / YFP BRET** ROS-Glo Steady-Glo Succinate-Glo Water-Glo

* GloMax Discover only (GM3000)
** GloMax Explorer only (GM3500)

Not sure if GloMax® Discover is the right choice for your lab?

Find the instrument that's right for your needs.Compare Plate Readers

GloMax® Discover Microplate Reader | Plate Reader (14)

Service and Support

One Call Supports It All

Promega supplies both the reagents and the instrument, so one call to Promega answers any questions you may have about assay chemistries or instrument performance.

Contact Technical Services

Ensure Minimal Instrument Downtime

  • Field Support and Loaner Programs
  • Service Packages
  • IQ and OQ Packages

Warranty and Service Agreements

  • Backed by a one-year warranty.
  • Additional warranty and service agreements are available.
  • For more information contact Promega Technical Services

Instrument Service and Support

Instrument Registration

GloMax® Discover Microplate Reader | Plate Reader (15)

Design Features

Instrument Specifications

Detection Modes Luminescence, Fluorescence Intensity, UV-Visible Absorbance, Filtered Luminescence, BRET and FRET
Sample Format 6, 12, 24, 48, 96 and 384-well plates
Tablet PC Windows® 8.1 or 10 Tablet PC with USB connection to instrument
Read Speed 96-well plate: less than 1 minute; 384-well plate: less than 3 minutes
Automation Compatibility Hardware and software accessible to 3rd party hardware/software control, including LIMS.
Dimensions 18.5in (46.9cm) width
19.5in (46.5cm) depth
10in (25.4cm) height without Tablet and PC mounted
16in (35.5cm) height with Tablet and PC mounted
Weight Approximately 60lbs. (27kg)
Power Requirements 120VA, 50/60 HZ
Warranty 1-year parts and labor warranty included
Regulatory Compliance For Research Use Only. Not for use in Diagnostic Procedures

Luminescence Module Specifications

Detector Top-reading, head-on photon counting photomultiplier tube (PMT)
Wavelength Range 350–700nm
Detection Limit 3 × 10-21moles of luciferase
Linear Dynamic Range 9 logs
Cross-talk Less than 3 × 10-5(white, 96-well plate, Corning 3912)
Filtered Luminescence Built-in filter paddle

Fluorescence Module Specifications

Detector PIN-photodiode
Light Source Wavelength-matched LED
Read Position Top reading
Wavelengths selection Filter module with 5 standard excitation and emission filters. Empty filter positions are available for custom excitation and emission wavelengths.
Wavelengths included UV (Ex: 365nm, Em: 415–445nm) Blue (Ex: 475nm, Em: 500–550nm) Green (Ex: 520nm, Em: 580–640nm) Red (Ex: 627nm, Em: 660–720nm) AFC (Ex: 405nm, Em: 495–505nm)
Detection Limit 2fmol fluorescence dye/200µl
Linear Dynamic Range >6 logs (assay dependent)

UV-Visible Absorbance Module Specifications

Detector Top-reading, head-on photon counting photomultiplier tube (PMT)
Light Source Xenon flash lamp
Spectra Range 200–600nm
Filter Wheel 9 absorbance filters included
Wavelengths included 230, 260, 280, 320, 405, 450, 490, 560 and 600nm 10nm band pass
Detection Limit 0.1 O.D.
Dynamic Range 0–4.0 O.D.

Injector System Specifications

Number of injectors (optional) Two injectors
Dispense Volume Range 5–200µl in 1µl increments
Plate Compatibility 6, 12, 24, 48, and 96-well plates
Injection Speed 20–500µl per second
Waste Collection Tray Volume Approximately 50ml
Void Volume 500µl

Heating System Specifications

Temperature Range Ambient to 45°C

Shaker System Specifications

Shaking Pattern Linear or orbital patterns
Shaking Intensity 100–500 cycles/minute

PC Requirements

Operating System Windows® 8.1 or 10 Pro, 64 bit, with USB connection to instrument
RAM 2GB
Disk Space 64GB
Other Requirements Microsoft.NET 4.0 Framework (full version), Microsoft Excel 2013 Professional

Available Separately

Product Catalog #
LuminometerLight Plate E6531
GloMax® Discover Luminescence Filter Paddle GM3011
GloMax® Discover Fluorescence Filter Paddle GM3012
GloMax® Discover96 Half-Position Aperture Assembly GM1050
GloMax® Dual Injectors with Pumps GM3030
Inner and Outer Injector Tubing, Natural GM3014
GloMax® Explorer Absorbance Module Upgrade GM3520
GloMax® Discover-Explorer Sales Rental E5301
GloMax® Discover or Explorer Installation Qualification SA1104
GloMax® Discover or Explorer Operational Qualification SA1105
GloMax® Discover or Explorer Installation and Operational Qualification SA1106
GloMax® Discover Standard Service Agreement SA4000
GloMax® Discover or ExplorerPreventive Maintenance SA4030

Protocols

Complete Protocol

GloMax® Discover SystemPDF (28536 KB) – English

Quick Protocols

GloMax® Discover System Quick Start GuidePDF (3036 KB) – English

GloMax Discover System Creating a New Protocol FB166PDF (450 KB) – English

Video Protocols

GloMax® Discover Microplate Reader | Plate Reader (16)

Specifications

SDS

Search for SDS

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

GloMax® Discover Microplate Reader | Plate Reader (17)

Patents and Disclaimers

Patent Pending.

Resources

Software and Firmware

  • GloMax® Discover
  • Protocols for GloMax® Discover and GloMax® Explorer Systems

Other

  • GloMax® Application Notes
  • How To Export Templates and Results Using the GloMax® Analysis Software
  • How To Edit a Graph Using the GloMax® Analysis Software
  • How To Create an Analysis Template Using the GloMax® Analysis Software
  • Measuring BRET Assays on the GloMax® Discover System
  • Replacing Injector Tubing on GloMax Discover or Explorer Microplate Reader
  • GloMax® Access Panel Installation Video
  • GloMax® Access Panel Removal Video

Similar Products

GloMax® Explorer System Easy-to-use, flexible multimode detection system. GM3500, GM3510 GloMax® 20/20 Luminometer Ultrasensitive single tube luminometer. E5311 GloMax® Navigator System Dedicated microplate luminometer. GM2000, GM2010 Quantus™ Fluorometer Two fluorescence channels for nucleic acid and protein quantitation. E6150

Frequently Used With

RealTime-Glo™ MT Cell Viability Assay A bioluminescent method to kinetically monitor viability in cell culture up to 72 hours. G9711, G9712, G9713 Bio-Glo™ Luciferase Assay System Bioluminescent detection reagent qualified for use with bioassays that utilize firefly luciferase. G7940, G7941 Caspase-Glo® 3/7 Assay System An easy-to-use, plate-based luminescent assay for detecting caspase-3/7 activity. G8090, G8091, G8093, G8092 NanoBiT® PPI Starter Systems Complementation reporter for detection of protein interactions in live cells. N2014, N2015, N2016
Luminometer Injector Tubing Cleaning Kit 70% Ethanol Solution and ATP-Free Water to use with Water-Glo™ 96 Kits for GloMax® Instrument injector cleaning. AM1110
Let's find the product that meets your needs.Talk to a Scientist Sabine Germany
GloMax® Discover Microplate Reader | Plate Reader (2024)

References

Top Articles
Latest Posts
Article information

Author: Jonah Leffler

Last Updated:

Views: 5985

Rating: 4.4 / 5 (65 voted)

Reviews: 88% of readers found this page helpful

Author information

Name: Jonah Leffler

Birthday: 1997-10-27

Address: 8987 Kieth Ports, Luettgenland, CT 54657-9808

Phone: +2611128251586

Job: Mining Supervisor

Hobby: Worldbuilding, Electronics, Amateur radio, Skiing, Cycling, Jogging, Taxidermy

Introduction: My name is Jonah Leffler, I am a determined, faithful, outstanding, inexpensive, cheerful, determined, smiling person who loves writing and wants to share my knowledge and understanding with you.